Invest in technology that is already a market trend (RFF) and is considered the gold standard for stretch marks and sagging treatments. The technology offers advanced regenerative, natural and organic treatments.
Through scientific research, we are moving towards the future of global aesthetics, with Fractional Radio Frequency. People are looking for less aggressive solutions for balance and full health in their lives.
More Information
Tonegold Model: This equipment does not allow expansions of new technologies, that is, it is a Fractional Radio Frequency equipment in full, pure, only with this platform (closed software) and without possibilities to attach additional gauntlets. Offer the luxury of rejuvenation to your patients, with results up to 3x faster! EQRAD038.00
Reasons to buy
Differences
- Results 3x faster than conventional radio frequency
- First fractional radio frequency (microneedles) developed exclusively for aesthetic area
- Comfort technology, which reduces the discomfort of the application ● Fractional Radiofrequency promotes the renewal of collagen, called tissue renewal, through controlled thermal damage, resulting from the injury caused by the temperature at the tip of the needles. Unpublished studies prove the safety and effectiveness of the world's first fractional radio frequency!
- Type 1 collagen production, 48% higher than conventional RF
- First fractional radio frequency (microneedles) developed exclusively for aesthetic area - national technology
- Gold-plated microneedles, the luxury of rejuvenation, to deliver efficient results in less time. Gold improves the conduction of radiofrequency and ensures safety in application, as it is hypoallergenic. The tips are disposable, single-use for each patient, to ensure biosafety
Application video
Watch the video and better understand the benefits
Included Technologies
Fractionated Radio frequency
It resembles the effect of fractional laser, promoting micro thermal lesions in the tissue, the objective is to protect the epidermis and deposit the greatest amount of energy (heat) in the deeper layers of the skin, to stimulate the formation of collagen in addition to leaving adjacent areas intact, accelerating tissue regeneration.
Technical Specifications
Linear Fractional Electrode
8 microneedles for expression lines, stretch marks and unsightly scar.
Matrix Fractional Electrode
25 microneedles for stretch marks, rejuvenation, unsightly scarring, facial and body skin sagging.
Contraindications
Spectra must not be used in patients with the following listed pathologies or symptoms: malignant tumors, heart diseases or pacemaker users, users of spinal or bladder stimulators, pregnant women or newborns, unknown skin lesions, patients under the age of 18, areas of skin in recent tanning conditions, trends in keloid formation or hypertrophic healing, open wounds at the application site, immunodeficient patients, patients with a history or treatment for epilepsy, active herpes infection in the treated region, metallic implants close to the treated regions, tattoo regions, history or treatment of coagulopathies, use of isotretinoin in the last 6 (six) months before treatment, applications on regions treated with Botulinum Toxin and/or filled with biomaterials in the last 6 (six) months.
Suggested Protocol for Body Tissue Flaccidity
1. Skin preparation The skin preparation is mandatory 15 to 21 days before application. Pre- application: the skin must be prepared with topical anesthetic following the recommendations and doses recommended by the manufacturers (posology). 2. Hygienization: Skin hygienization must be performed before any procedure, using products specific to the skin type of each patient. The treatment must be done with clean and dry skin, any water residue on the surface of the skin can absorb energy and prevent its spread to the dermis. 3. Application of Fractional Radiofrequency: Tip indicated: 'Fractional' Select the program Body skin flaccidity. Parameters: 20 mJ. Position the coupling plate directly on the skin contralateral to the treated area. The application technique consists of applying radiofrequency to the full extent of flaccidity. It is necessary to have a moderate pressure of the electrode on the skin and also to activate the pedal to emit the radio frequency. The power applied will depend on the patient's tolerance. 4. Conclusion: Guide the patient to take proper care in home care. Finalize the procedure with the application of specific drug delivery for skin flaccidity.
Technical Characteristics
Electrical characteristics for power: Standard power cable for alternating current circuits with connection to ground; Supply voltage 127 ‐ 220 V~; Supply frequency: 50 ‐ 60 Hz; Maximum consumption power: 145 VA; Average consumption: 0.100 kWh; Fuses: 2 x 2.5A (20AG T2.5AL 250V); Current: 905mA (max.); Overvoltage category II; Pollution degree II. Classification Equipment: Equipment Class: I; Equipment with applied part of type BF; IP20: Equipment not protected against harmful penetration of water; IP43: The Pedal is protected against solid objects of Ø1.0 mm and larger and protected against water projections; Mode of operation: Continuous Operation; Equipment not suitable for use in the presence of a flammable anesthetic mixture with air, O2 or N2O. Risk Group 2, according to IEC 62471:2006.MF Fractional RF Flat
Output Specifications:
One active electrode - ##DISPOSABLE; • Coupling – Resistive (Gold plated); • Contact Area – 1 cm2 (25 contact points); • Detachable Cable - Yes; • Coupling Medium – Absent; • Frequency – 650 kHz (modulated in pulses); • Maximum Energy – 65 mJ; • Temperature Sensor – Absent; • Power Control – Absent; • Joint use with return plate – Yes; • Maximum useful heating depth – 2 mm; • Light for indication of operating status. MFL Linear Fractional RF Gauntlet: An active electrode - ##DISPOSABLE; • Coupling – Resistive (Gold plated); • Contact area – 1 cm (8 points of contact); • Detachable Cable - Yes; • Coupling medium – Absent; • Frequency – 650 kHz (modulated in pulses); • Maximum Energy – 65 mJ; • Temperature Sensor – Absent; • Power control – Absent; • Joint use with return plate – Yes; • Maximum useful heating depth – 2 mm; • Light for indication of operating state.
ANVISA Registration
Number 10411520022
Warranty
2 years
Treatment indications
SPECTRA platform brings together different technologies that are based on different physiological and energetic processes, more than one technique can be used for some conditions. In general, the use of the SPECTRA platform is indicated as complementary techniques for the following treatments: facial rejuvenation, attenuation of wrinkles and expression marks, facial and neck lifting, reduction of tissue sagging, treatment of stretch marks, reduction of active acne, treatment of atrophic scars, reduction of localized fat, relief of musculoskeletal pain, cellulite.
Check out reviews from people who have already purchased
Spectra Artis Standard
Fractional Radiofrequency TonegoldTonegold Model: This equipment does not allow expansions of new technologies, that is, it is a Fractional Radio Frequency equipment in full, pure, only with this platform (closed software) and without possibilities to attach additional gauntlets. Offer the luxury of rejuvenation to your patients, with results up to 3x faster! EQRAD038.00
Invest in technology that is already a market trend (RFF) and is considered the gold standard for stretch marks and sagging treatments. The technology offers advanced regenerative, natural and organic treatments.
Through scientific research, we are moving towards the future of global aesthetics, with Fractional Radio Frequency. People are looking for less aggressive solutions for balance and full health in their lives.
- Results 3x faster than conventional radio frequency
- First fractional radio frequency (microneedles) developed exclusively for aesthetic area
- Comfort technology, which reduces the discomfort of the application ● Fractional Radiofrequency promotes the renewal of collagen, called tissue renewal, through controlled thermal damage, resulting from the injury caused by the temperature at the tip of the needles. Unpublished studies prove the safety and effectiveness of the world's first fractional radio frequency!
- Type 1 collagen production, 48% higher than conventional RF
- First fractional radio frequency (microneedles) developed exclusively for aesthetic area - national technology
- Gold-plated microneedles, the luxury of rejuvenation, to deliver efficient results in less time. Gold improves the conduction of radiofrequency and ensures safety in application, as it is hypoallergenic. The tips are disposable, single-use for each patient, to ensure biosafety
Watch the video and better understand the benefits
Fractionated Radio frequency
It resembles the effect of fractional laser, promoting micro thermal lesions in the tissue, the objective is to protect the epidermis and deposit the greatest amount of energy (heat) in the deeper layers of the skin, to stimulate the formation of collagen in addition to leaving adjacent areas intact, accelerating tissue regeneration.
Linear Fractional Electrode
8 microneedles for expression lines, stretch marks and unsightly scar.
Matrix Fractional Electrode
25 microneedles for stretch marks, rejuvenation, unsightly scarring, facial and body skin sagging.
Contraindications
Spectra must not be used in patients with the following listed pathologies or symptoms: malignant tumors, heart diseases or pacemaker users, users of spinal or bladder stimulators, pregnant women or newborns, unknown skin lesions, patients under the age of 18, areas of skin in recent tanning conditions, trends in keloid formation or hypertrophic healing, open wounds at the application site, immunodeficient patients, patients with a history or treatment for epilepsy, active herpes infection in the treated region, metallic implants close to the treated regions, tattoo regions, history or treatment of coagulopathies, use of isotretinoin in the last 6 (six) months before treatment, applications on regions treated with Botulinum Toxin and/or filled with biomaterials in the last 6 (six) months.
Suggested Protocol for Body Tissue Flaccidity
1. Skin preparation The skin preparation is mandatory 15 to 21 days before application. Pre- application: the skin must be prepared with topical anesthetic following the recommendations and doses recommended by the manufacturers (posology). 2. Hygienization: Skin hygienization must be performed before any procedure, using products specific to the skin type of each patient. The treatment must be done with clean and dry skin, any water residue on the surface of the skin can absorb energy and prevent its spread to the dermis. 3. Application of Fractional Radiofrequency: Tip indicated: 'Fractional' Select the program Body skin flaccidity. Parameters: 20 mJ. Position the coupling plate directly on the skin contralateral to the treated area. The application technique consists of applying radiofrequency to the full extent of flaccidity. It is necessary to have a moderate pressure of the electrode on the skin and also to activate the pedal to emit the radio frequency. The power applied will depend on the patient's tolerance. 4. Conclusion: Guide the patient to take proper care in home care. Finalize the procedure with the application of specific drug delivery for skin flaccidity.
Technical Characteristics
Electrical characteristics for power: Standard power cable for alternating current circuits with connection to ground; Supply voltage 127 ‐ 220 V~; Supply frequency: 50 ‐ 60 Hz; Maximum consumption power: 145 VA; Average consumption: 0.100 kWh; Fuses: 2 x 2.5A (20AG T2.5AL 250V); Current: 905mA (max.); Overvoltage category II; Pollution degree II. Classification Equipment: Equipment Class: I; Equipment with applied part of type BF; IP20: Equipment not protected against harmful penetration of water; IP43: The Pedal is protected against solid objects of Ø1.0 mm and larger and protected against water projections; Mode of operation: Continuous Operation; Equipment not suitable for use in the presence of a flammable anesthetic mixture with air, O2 or N2O. Risk Group 2, according to IEC 62471:2006.MF Fractional RF Flat
Output Specifications:
One active electrode - ##DISPOSABLE; • Coupling – Resistive (Gold plated); • Contact Area – 1 cm2 (25 contact points); • Detachable Cable - Yes; • Coupling Medium – Absent; • Frequency – 650 kHz (modulated in pulses); • Maximum Energy – 65 mJ; • Temperature Sensor – Absent; • Power Control – Absent; • Joint use with return plate – Yes; • Maximum useful heating depth – 2 mm; • Light for indication of operating status. MFL Linear Fractional RF Gauntlet: An active electrode - ##DISPOSABLE; • Coupling – Resistive (Gold plated); • Contact area – 1 cm (8 points of contact); • Detachable Cable - Yes; • Coupling medium – Absent; • Frequency – 650 kHz (modulated in pulses); • Maximum Energy – 65 mJ; • Temperature Sensor – Absent; • Power control – Absent; • Joint use with return plate – Yes; • Maximum useful heating depth – 2 mm; • Light for indication of operating state.
ANVISA Registration
Number 10411520022
Warranty
2 years
Treatment indications
SPECTRA platform brings together different technologies that are based on different physiological and energetic processes, more than one technique can be used for some conditions. In general, the use of the SPECTRA platform is indicated as complementary techniques for the following treatments: facial rejuvenation, attenuation of wrinkles and expression marks, facial and neck lifting, reduction of tissue sagging, treatment of stretch marks, reduction of active acne, treatment of atrophic scars, reduction of localized fat, relief of musculoskeletal pain, cellulite.
Check out some clinical results
Click on the arrows and drag to the side to see the incredible resultsFAQ
The results can be compared to the Fractional CO2 Laser, but with more safety in the aesthetic area
Both types of Radiofrequency focus on stimulating collagen production. Non-ablative RF by diathermy is applied through multiple passes of the electrodes of different sizes on the skin and has indications, such as complementary treatment for cellulite, localized fat and tissue flaccidity. Fractional Radiofrequency is applied through microneedles in order to deposit greater amount of energy (heat) in the deeper layers to stimulate collagen formation.
Because gold has a higher conductivity (conducts electrical current better) and gold is more hypoallergenic, that is, less possibility of allergies.
The Fractional RF electrodes have different depths that can vary from 0.5 mm to 3.0 mm in the fractional type, while in the linear type the depth is 1.5 mm.